PVB Testing in Mount Lebanon, PA

The pressure vacuum breaker, or PVB, is the brass device sticking out of the ground near your sprinkler system with a bonnet on top and two small test cocks. It is the most common backflow preventer on residential irrigation.

A PVB test checks two things. The air inlet has to open when pressure in the body drops to about 1.0 psi. The check valve has to hold at least 1.0 psid in the direction of flow.

The usual failures are a cracked bonnet from a freeze, a stuck poppet, or a check that leaks because the rubber has gone hard after years in the sun. Water spitting out from under the canopy when the system starts is a sign the poppet is not seating.

A PVB must sit at least 12 inches above the highest sprinkler head it serves. If yours is lower, it may not pass inspection even with good readings.

Grizzly Backflow & Plumbing connects Mount Lebanon, PA homeowners with testers for PVB testing and backflow prevention repairs. Call (833) 990-5874.

How it works

Four steps to backflow testing in Mount Lebanon, PA

  1. 01

    Grab your notice

    Have the utility letter handy. It lists the device, serial number and due date.

  2. 02

    Talk it through

    Call (833) 990-5874. We go over the device type and the price before anything is booked.

  3. 03

    Test day

    A certified tester reads each check and the relief valve on a calibrated gauge.

  4. 04

    Report filed

    The report goes to your water utility, and you keep a copy for your records.

Coverage

Backflow Testing Services Across Mount Lebanon, PA

Backflow testing for the neighborhoods and ZIP codes around Mount Lebanon, PA.

Neighborhoods we cover for backflow testing

  • Mount Lebanon
  • Washington Park
  • Sunset Hills
  • Hoodridge
  • Beverly Heights

Backflow testing FAQs

Questions about backflow testing

Questions we hear most often about PVB Testing in Mount Lebanon, PA.

Talk to a person
What is the difference between an RPZ and a double check valve?
Both have two independent check valves. An RPZ adds a relief valve between the checks that discharges water to atmosphere if the checks leak, which is why it is required on high-hazard connections.
Does my lawn sprinkler system in Mount Lebanon, PA need a backflow preventer?
Almost every US plumbing code requires one on irrigation, since fertilizer, pesticide and standing water at the heads can siphon back. The device type depends on local code and how the system is laid out.
What does a failed backflow test mean?
A check valve or the relief valve did not hold its required pressure differential. The device needs repair or replacement, then a retest before a passing report can be filed.
What is a cross-connection?
Any point where drinking water piping can come into contact with a non-potable source. Common examples are a hose in a bucket, a boiler fill line and an irrigation system.
Who sends the test report to the water utility?
The tester usually files it, either on the utility's paper form or through its online portal. Ask for a copy for your own records.

Book a backflow test

Backflow Test Due in Mount Lebanon, PA? Call now.

Certified testers for backflow testing in Mount Lebanon, PA. Call (833) 990-5874 and we go through the device and the price before anything is booked.

(833) 990-5874
Phone · (833) 990-5874
Call (833) 990-5874 Enquire